Filter Results By:

Products

Applications

Manufacturers

Ground Resistance

Evaluation of the conductance of earth grounding.

See Also: Ground Resistance Clamps, Ground Resistance Testers, Surface Resistivity


Showing results: 91 - 105 of 141 items found.

  • Earth Leakage Breaker And Residual Current Device

    IGR Series - Jaeshininfo Co. Ltd

    IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.

  • Miller 400A

    44500 - M. C. Miller Company

    Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source

  • Drop Test Machine

    Shanghai Linpin Instrument

    Single-wing Drop Test Machine Simulate the drop conditions of packaged products when different faces, edges and corners fall to the ground from different heights, thus to understand the damage of the product and evaluate the drop height and impact resistance that the packaging materials can endure while falling down, so as to improve and optimize package design according to actual conditions of the product and national standard range.

  • Electrical Safety Multi-Analyzer

    TOS9300 Series - Kikusui Electronics Corp.

    The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • Micro-Ohmmeter and Loop Resistance Tester

    LRT 6000 - ATEQ Aviation

    LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.

  • Megohm Meter

    Fieldpiece Instruments, Inc

    Digital Megohm Meter, model SMG5, is a compact standalone meter designed for checking HVAC compressor insulation. The SMG5 provides a 1000V voltage source, monitors current, and displays the resistance between the test points. Maximum current output is <1mA. It can be used to determine the condition of insulation from winding to ground in a motor, compressor, or transformer. Includes a case, alligator clip lead tip and leads with removable tips.

  • Wrist Strap Monitors

    Botron Inc.

    Single conductor (more commonly called single wire) ESD wrist strap monitors detect capacitance. These simplified monitors sense the input connection but do not discern precision resistance. They also offer additional value by monitoring the worksurface (ESD Mat) and the ground connection. The built-in LED offers local visual alerts, and a small piezo buzzer offers a nice clear audible alert to the operator at the bench.

  • Digital Electrical Network Analyzer

    1826 NA - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.

  • Solar Connectors & Adapters

    TE Connectivity Ltd.

    Our SOLARLOK photovoltaic connectors are designed for easy, quick and reliable DC connections for solar technology. With a precision-engineered design, these help achieve the lowest contact resistance to reduce power losses. Our DC Plug and splice connectors provide reliable connection, reducing up to 80% installation time with Insulation Displacement Contact (IDC) technology. Our grounding connectors enable installers to ground the photovoltaic system and create flexibility at the installation.

  • Resistance Grounded Systems (HRG/LRG)

    Bender Inc.

    Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.

  • Electrical Safety Testers

    Shanghai MCP Corp

    .AC/DC withstand voltage test & ground bond test .Insulation resistance test(ST60).Arc detection.Zero crossing turn-on,turn-off operation switch.Controllable ramp-up time .Ture RMS cut-off current measurement .Automatic fail indicator of alarm lamp and buzzer.VFD display.Standard PLC interface .Option RS-232,RS-485

  • Electronic Primary Injection Test Set

    eKAM - Altanova Group

    eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a large graphical display, that adjusts the output, and one current unit (up to 2000, 3000, 5000A). It can also perform Step and Touch tests and ground resistance tests.

  • Voltage Probe

    KHZ43201 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.

  • Miller 400D

    44550 - M. C. Miller Company

    No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)

  • Multifunctional Safety Tests

    LXinstruments GmbH

    Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test